{"id":2879,"date":"2026-02-27T01:27:22","date_gmt":"2026-02-27T01:27:22","guid":{"rendered":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/"},"modified":"2026-02-27T01:27:22","modified_gmt":"2026-02-27T01:27:22","slug":"shaffer-grading-definition-uses-and-clinical-overview","status":"publish","type":"post","link":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/","title":{"rendered":"Shaffer grading: Definition, Uses, and Clinical Overview"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Shaffer grading Introduction (What it is)<\/h2>\n\n\n\n<p>Shaffer grading is a clinical scale used to describe how open or narrow the eye\u2019s drainage angle is.<br\/>\nIt is most commonly recorded during gonioscopy, an exam where a clinician views the angle using a special contact lens and microscope.<br\/>\nThe grading helps summarize a key glaucoma-related finding in a standardized way.<br\/>\nIn plain terms, it estimates how much \u201cspace\u201d exists where eye fluid drains.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Shaffer grading used (Purpose \/ benefits)<\/h2>\n\n\n\n<p>Shaffer grading is used to document the width of the anterior chamber angle\u2014the junction where the cornea meets the iris and where aqueous humor (the eye\u2019s internal fluid) exits through the trabecular meshwork. Angle anatomy matters because it can influence intraocular pressure (IOP) and the risk of angle closure, a mechanism that can contribute to glaucoma.<\/p>\n\n\n\n<p>Key purposes and benefits include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Risk stratification for angle closure:<\/strong> A narrower angle may be more likely to become blocked under certain conditions (for example, when the pupil dilates), while a wider angle is generally less likely to close due to crowding alone.<\/li>\n<li><strong>Clear communication:<\/strong> A Shaffer grading entry in the chart quickly communicates angle configuration to other clinicians.<\/li>\n<li><strong>Tracking change over time:<\/strong> Repeating gonioscopy and recording Shaffer grading can help document whether angle appearance is stable or changing (for example, with aging, lens changes, or after procedures).<\/li>\n<li><strong>Supporting diagnosis:<\/strong> Angle findings help clinicians differentiate broad categories such as open-angle vs angle-closure mechanisms in glaucoma evaluation.<\/li>\n<li><strong>Guiding next diagnostic steps:<\/strong> A narrow angle on Shaffer grading may prompt further assessment (for example, indentation gonioscopy to check for appositional closure) or imaging, depending on the case.<\/li>\n<\/ul>\n\n\n\n<p>Shaffer grading does not treat a condition by itself; it is a descriptive tool that supports clinical decision-making.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Indications (When ophthalmologists or optometrists use it)<\/h2>\n\n\n\n<p>Shaffer grading is typically used in situations such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Glaucoma evaluation (suspected or established)<\/li>\n<li>Elevated intraocular pressure or unexplained optic nerve findings<\/li>\n<li>Screening for narrow angles, especially in higher-risk anatomy (varies by clinician and case)<\/li>\n<li>Assessment before or after angle-related treatments (for example, laser peripheral iridotomy) to document angle status<\/li>\n<li>Evaluation of intermittent symptoms that could relate to angle narrowing (varies by clinician and case)<\/li>\n<li>Preoperative planning for certain intraocular surgeries (where angle anatomy may influence approach)<\/li>\n<li>Follow-up of known narrow angles to document stability over time<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Contraindications \/ when it\u2019s NOT ideal<\/h2>\n\n\n\n<p>Shaffer grading depends on being able to perform gonioscopy and obtain a clear view of the angle structures. Situations where it may be difficult, less reliable, or deferred include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Poor corneal clarity<\/strong> (for example, significant corneal edema or scarring) that prevents adequate visualization<\/li>\n<li><strong>Active eye infection or significant inflammation<\/strong> where contact lens examination may be postponed (varies by clinician and case)<\/li>\n<li><strong>Recent eye trauma or suspected open-globe injury<\/strong>, where contact procedures are generally avoided<\/li>\n<li><strong>Inability to cooperate with the exam<\/strong> (for example, severe discomfort, certain neurologic or movement limitations), reducing reliability<\/li>\n<li><strong>Marked surface dryness or epithelial defects<\/strong> that may make contact lens examination less tolerable (varies by clinician and case)<\/li>\n<li><strong>Anatomic complexity where a single number is too simplistic<\/strong>, such as unusual iris configuration or post-surgical angle changes; other descriptors or imaging may be added<\/li>\n<\/ul>\n\n\n\n<p>When Shaffer grading is not feasible or is limited, clinicians may use other approaches such as anterior segment optical coherence tomography (AS-OCT) or ultrasound biomicroscopy (UBM), depending on availability and the clinical question.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How it works (Mechanism \/ physiology)<\/h2>\n\n\n\n<p>Shaffer grading is based on direct visualization of the anterior chamber angle during gonioscopy. It estimates the <strong>angle between the inner cornea and the iris<\/strong> near the trabecular meshwork, expressed in approximate degrees and linked to which angle structures are visible.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Relevant anatomy (explained simply)<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Cornea:<\/strong> The clear front \u201cwindow\u201d of the eye.<\/li>\n<li><strong>Iris:<\/strong> The colored tissue that forms the pupil.<\/li>\n<li><strong>Anterior chamber:<\/strong> The fluid-filled space between cornea and iris.<\/li>\n<li><strong>Anterior chamber angle:<\/strong> The \u201ccorner\u201d where cornea and iris meet.<\/li>\n<li><strong>Trabecular meshwork:<\/strong> The primary drainage tissue for aqueous humor.<\/li>\n<li><strong>Schwalbe\u2019s line, scleral spur, ciliary body band:<\/strong> Landmark structures seen on gonioscopy that help confirm how open the angle is.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">The Shaffer grading concept<\/h3>\n\n\n\n<p>In general terms, the scale runs from a <strong>closed angle<\/strong> to a <strong>wide-open angle<\/strong>, commonly recorded as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Grade 0:<\/strong> 0\u00b0 \u2014 closed angle (no angle structures visible due to closure)<\/li>\n<li><strong>Grade 1:<\/strong> ~10\u00b0 \u2014 extremely narrow; typically only the most anterior landmark may be seen<\/li>\n<li><strong>Grade 2:<\/strong> ~20\u00b0 \u2014 moderately narrow; angle structures associated with drainage may be partially visible<\/li>\n<li><strong>Grade 3:<\/strong> ~25\u201335\u00b0 \u2014 open angle; deeper structures are visible<\/li>\n<li><strong>Grade 4:<\/strong> ~35\u201345\u00b0 \u2014 wide open; the deepest landmarks are visible<\/li>\n<\/ul>\n\n\n\n<p>Clinicians may also add descriptive notes (for example, pigment, iris contour, peripheral anterior synechiae, or neovascularization) because a single grade does not capture every clinically relevant detail.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Onset, duration, reversibility<\/h3>\n\n\n\n<p>Shaffer grading is not a treatment, so \u201conset\u201d and \u201cduration\u201d do not apply in the usual way. The grade is a <strong>snapshot finding<\/strong> that can change with pupil size, lighting, accommodation, age-related lens thickening, and certain interventions. For this reason, gonioscopy is typically repeated when clinically relevant.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Shaffer grading Procedure overview (How it\u2019s applied)<\/h2>\n\n\n\n<p>Shaffer grading is recorded during an eye exam, most often as part of gonioscopy. While gonioscopy is a clinical procedure, Shaffer grading is the <strong>documentation system<\/strong> used to summarize what is seen.<\/p>\n\n\n\n<p>A high-level workflow often looks like this:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\n<p><strong>Evaluation \/ exam<\/strong>\n   &#8211; Review of symptoms and risk factors (as appropriate)\n   &#8211; Measurement of intraocular pressure and assessment of the optic nerve and visual function (varies by visit type)<\/p>\n<\/li>\n<li>\n<p><strong>Preparation<\/strong>\n   &#8211; The clinician explains the test and positions the patient at a slit lamp microscope.\n   &#8211; Numbing drops are commonly used so the contact lens can rest on the eye comfortably (practice varies).\n   &#8211; A coupling fluid may be applied to the lens to improve optical clarity (varies by lens type).<\/p>\n<\/li>\n<li>\n<p><strong>Intervention \/ testing<\/strong>\n   &#8211; A gonioscopy lens is gently placed on the eye.\n   &#8211; The clinician views the angle in different quadrants and identifies landmark structures.\n   &#8211; A <strong>Shaffer grading<\/strong> value is assigned for each quadrant (or an overall grade may be recorded), depending on documentation style.\n   &#8211; In some cases, <strong>indentation gonioscopy<\/strong> is performed to help distinguish simple contact closure (appositional) from adhesions (synechiae), but this is a separate maneuver from grading.<\/p>\n<\/li>\n<li>\n<p><strong>Immediate checks<\/strong>\n   &#8211; The lens is removed and the eye is briefly checked for comfort and surface integrity (varies by clinician and case).\n   &#8211; Vision may be slightly blurred temporarily from drops or the coupling fluid.<\/p>\n<\/li>\n<li>\n<p><strong>Follow-up<\/strong>\n   &#8211; The grade is interpreted alongside other findings (IOP, optic nerve appearance, imaging, and visual field testing when relevant).\n   &#8211; Repeat assessment timing varies by clinician and case.<\/p>\n<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Types \/ variations<\/h2>\n\n\n\n<p>Shaffer grading is one of several ways to describe angle width. Common variations in practice include differences in <strong>how the grade is recorded<\/strong>, and what additional descriptors are included.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How Shaffer grading may be recorded<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>By quadrant:<\/strong> Separate grades for superior, inferior, nasal, and temporal angles, since angle width can vary around the eye.<\/li>\n<li><strong>Overall summary:<\/strong> A single representative grade, sometimes combined with comments about the narrowest quadrant.<\/li>\n<li><strong>With risk-oriented interpretation:<\/strong> Some clinicians associate lower grades with higher concern for angle closure mechanisms, but the exact interpretation varies by clinician and case.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Related gonioscopy variations that affect what is seen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Static vs dynamic (indentation) gonioscopy:<\/strong> Indentation can temporarily open an appositionally closed angle, helping clarify anatomy; the Shaffer grade may be interpreted differently depending on whether indentation is used.<\/li>\n<li><strong>Different gonioscopy lenses:<\/strong> One-, two-, or four-mirror lenses may be used. Lens choice can influence technique and view, but the Shaffer grading concept remains the same.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Other angle assessment systems often discussed alongside Shaffer grading<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Spaeth grading system:<\/strong> More detailed, including iris insertion and configuration, not just angle width.<\/li>\n<li><strong>Van Herick technique:<\/strong> A slit-lamp estimation of peripheral anterior chamber depth (not gonioscopy). It can suggest a narrow angle but does not directly visualize the trabecular meshwork.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Pros and cons<\/h2>\n\n\n\n<p>Pros:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Summarizes anterior chamber angle width in a simple, widely recognized scale<\/li>\n<li>Supports consistent documentation across visits and between clinicians<\/li>\n<li>Helps communicate glaucoma-relevant anatomy in a compact form<\/li>\n<li>Can be recorded per quadrant to capture regional differences<\/li>\n<li>Pairs well with descriptive gonioscopy notes (pigment, synechiae, vessels)<\/li>\n<li>Low equipment burden beyond standard gonioscopy tools<\/li>\n<\/ul>\n\n\n\n<p>Cons:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A single grade can oversimplify complex angle anatomy<\/li>\n<li>Depends on examiner skill and interpretation; inter-observer variability can occur<\/li>\n<li>Visualization can be limited by corneal clarity, patient comfort, or cooperation<\/li>\n<li>Angle appearance can change with lighting and pupil size, affecting repeatability<\/li>\n<li>Does not directly measure intraocular pressure or optic nerve damage<\/li>\n<li>Does not fully describe iris configuration (for example, plateau iris) without added descriptors<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Aftercare &amp; longevity<\/h2>\n\n\n\n<p>Because Shaffer grading is a recorded observation rather than a treatment, \u201caftercare\u201d mainly relates to the <strong>gonioscopy exam experience<\/strong> and to how results are used over time.<\/p>\n\n\n\n<p>General points that can affect the usefulness and \u201clongevity\u201d of the findings include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Quality of the view during the exam:<\/strong> Tear film stability, corneal clarity, and patient comfort can influence visualization and documentation.<\/li>\n<li><strong>Physiologic changes over time:<\/strong> Natural lens growth with age and changes in iris behavior can narrow angles in some people; the recorded grade may therefore change over months to years (varies by clinician and case).<\/li>\n<li><strong>Lighting and pupil size:<\/strong> Angle width can appear different in bright vs dim conditions, so clinicians often note the exam conditions implicitly by standardizing technique.<\/li>\n<li><strong>Coexisting eye conditions:<\/strong> Inflammation, trauma, or prior surgery can alter the angle and may require additional description beyond Shaffer grading.<\/li>\n<li><strong>Follow-up consistency:<\/strong> Repeated evaluations are most comparable when technique and documentation style are consistent, but real-world practice varies.<\/li>\n<\/ul>\n\n\n\n<p>If temporary blur or mild irritation occurs after gonioscopy, it is typically related to the exam drops or lens contact rather than the grading itself; individual experiences vary.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Alternatives \/ comparisons<\/h2>\n\n\n\n<p>Shaffer grading is one tool among several for evaluating and documenting the anterior chamber angle. Comparisons are best understood in terms of <strong>what each method measures<\/strong> and <strong>what it is used for<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Shaffer grading (gonioscopy-based) vs observation\/monitoring<\/strong><\/li>\n<li>\n<p>Shaffer grading is part of structured monitoring. Observation alone without angle assessment may miss important anatomic details in patients where angle status is relevant.<\/p>\n<\/li>\n<li>\n<p><strong>Shaffer grading vs Van Herick<\/strong><\/p>\n<\/li>\n<li>Van Herick is a quick, non-contact slit-lamp estimation of peripheral chamber depth and can suggest a narrow angle.<\/li>\n<li>\n<p>Shaffer grading requires gonioscopy and provides a direct view of angle landmarks, which is why gonioscopy is often considered necessary for definitive angle assessment.<\/p>\n<\/li>\n<li>\n<p><strong>Shaffer grading vs AS-OCT \/ UBM imaging<\/strong><\/p>\n<\/li>\n<li>AS-OCT and UBM provide cross-sectional images and can be helpful when gonioscopy is difficult or when documenting configuration in a more visual, measurable way.<\/li>\n<li>\n<p>Gonioscopy with Shaffer grading allows direct clinical assessment of landmarks and additional findings (pigment, abnormal vessels, synechiae) that may be less straightforward on some imaging modalities. Availability and interpretation vary by clinic and device.<\/p>\n<\/li>\n<li>\n<p><strong>Shaffer grading vs more detailed angle grading systems (for example, Spaeth)<\/strong><\/p>\n<\/li>\n<li>Shaffer grading emphasizes angle width.<\/li>\n<li>More detailed systems incorporate iris insertion and configuration, which can matter in certain narrow-angle mechanisms. Some clinicians use both: a Shaffer grade plus descriptive notes.<\/li>\n<\/ul>\n\n\n\n<p>Overall, Shaffer grading is often used as a practical, standardized shorthand within a broader glaucoma and anterior segment evaluation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Shaffer grading Common questions (FAQ)<\/h2>\n\n\n\n<p><strong>Q: What does a Shaffer grading number actually mean?<\/strong><br\/>\nIt is an estimate of how open the eye\u2019s drainage angle is, typically expressed as a grade from 0 to 4. Lower grades correspond to narrower angles, while higher grades correspond to wider angles. Clinicians interpret the number alongside the visible angle structures and other exam findings.<\/p>\n\n\n\n<p><strong>Q: Is Shaffer grading the same as diagnosing glaucoma?<\/strong><br\/>\nNo. Shaffer grading describes angle anatomy, not optic nerve damage or visual field loss. Glaucoma assessment usually includes intraocular pressure, optic nerve evaluation, and sometimes imaging and visual field testing, with angle findings providing important context.<\/p>\n\n\n\n<p><strong>Q: Does the gonioscopy exam for Shaffer grading hurt?<\/strong><br\/>\nMany people find it more strange than painful. Numbing drops are commonly used, and the lens rests gently on the eye. Comfort varies by person, ocular surface sensitivity, and clinician technique.<\/p>\n\n\n\n<p><strong>Q: How long do Shaffer grading \u201cresults\u201d last?<\/strong><br\/>\nShaffer grading is a documentation of what was seen at that visit. Angle anatomy can appear different under different lighting or pupil conditions and can change over time, so the grade may be rechecked when clinically relevant.<\/p>\n\n\n\n<p><strong>Q: Can Shaffer grading change from one visit to another?<\/strong><br\/>\nYes. Differences can reflect true anatomic change (for example, age-related lens changes) or differences in exam conditions (lighting, pupil size) and technique. Some variability between clinicians can also occur.<\/p>\n\n\n\n<p><strong>Q: If my Shaffer grading is low, does that mean an emergency?<\/strong><br\/>\nNot necessarily. A narrow angle can be a risk factor for angle-closure mechanisms, but urgency depends on the full clinical picture, including symptoms and pressure. Clinicians interpret the finding with other exam data; urgency varies by clinician and case.<\/p>\n\n\n\n<p><strong>Q: Are there risks to the test used to determine Shaffer grading?<\/strong><br\/>\nGonioscopy is commonly performed in eye care and is generally considered low risk when done appropriately. Temporary blur, mild irritation, or light sensitivity can occur. Rare complications and individual risk considerations vary by clinician and case.<\/p>\n\n\n\n<p><strong>Q: How much does Shaffer grading or gonioscopy cost?<\/strong><br\/>\nCosts vary widely by clinic setting, country, insurance coverage, and whether it is bundled into a comprehensive eye exam or billed as part of a medical evaluation. The most accurate cost information usually comes from the specific clinic or insurer.<\/p>\n\n\n\n<p><strong>Q: Can I drive or use screens after the exam?<\/strong><br\/>\nThis depends on whether your eyes were dilated and how your vision feels after drops or the contact lens exam. Some people notice temporary blur or light sensitivity. Timing and precautions vary by clinician and case.<\/p>\n\n\n\n<p><strong>Q: Why might my clinician add notes instead of just a Shaffer grading number?<\/strong><br\/>\nAngle health involves more than width alone. Notes about pigment, iris contour, scar-like adhesions (peripheral anterior synechiae), or abnormal vessels can be clinically important. Shaffer grading is often used as the \u201cheadline,\u201d with descriptive findings providing the full context.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Shaffer grading is a clinical scale used to describe how open or narrow the eye\u2019s drainage angle is. It is most commonly recorded during gonioscopy, an exam where a clinician views the angle using a special contact lens and microscope. The grading helps summarize a key glaucoma-related finding in a standardized way. In plain terms, it estimates how much \u201cspace\u201d exists where eye fluid drains.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-2879","post","type-post","status-publish","format-standard","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals\" \/>\n<meta property=\"og:description\" content=\"Shaffer grading is a clinical scale used to describe how open or narrow the eye\u2019s drainage angle is. It is most commonly recorded during gonioscopy, an exam where a clinician views the angle using a special contact lens and microscope. The grading helps summarize a key glaucoma-related finding in a standardized way. In plain terms, it estimates how much \u201cspace\u201d exists where eye fluid drains.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/\" \/>\n<meta property=\"og:site_name\" content=\"Best Eye Hospitals\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-27T01:27:22+00:00\" \/>\n<meta name=\"author\" content=\"dreye\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"dreye\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/\",\"url\":\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/\",\"name\":\"Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals\",\"isPartOf\":{\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/#website\"},\"datePublished\":\"2026-02-27T01:27:22+00:00\",\"author\":{\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/4021f481cfccb939861999010538024c\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.besteyehospitals.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shaffer grading: Definition, Uses, and Clinical Overview\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/#website\",\"url\":\"https:\/\/www.besteyehospitals.com\/blog\/\",\"name\":\"My blog\",\"description\":\"Connecting You to the World\u2019s Best Eye Hospitals\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.besteyehospitals.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/4021f481cfccb939861999010538024c\",\"name\":\"dreye\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/69eb63e7f3249514583055a53b7943b46015043634892a817520c7b299ddf648?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/69eb63e7f3249514583055a53b7943b46015043634892a817520c7b299ddf648?s=96&d=mm&r=g\",\"caption\":\"dreye\"},\"url\":\"https:\/\/www.besteyehospitals.com\/blog\/author\/dreye\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/","og_locale":"en_US","og_type":"article","og_title":"Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals","og_description":"Shaffer grading is a clinical scale used to describe how open or narrow the eye\u2019s drainage angle is. It is most commonly recorded during gonioscopy, an exam where a clinician views the angle using a special contact lens and microscope. The grading helps summarize a key glaucoma-related finding in a standardized way. In plain terms, it estimates how much \u201cspace\u201d exists where eye fluid drains.","og_url":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/","og_site_name":"Best Eye Hospitals","article_published_time":"2026-02-27T01:27:22+00:00","author":"dreye","twitter_card":"summary_large_image","twitter_misc":{"Written by":"dreye","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/","url":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/","name":"Shaffer grading: Definition, Uses, and Clinical Overview - Best Eye Hospitals","isPartOf":{"@id":"https:\/\/www.besteyehospitals.com\/blog\/#website"},"datePublished":"2026-02-27T01:27:22+00:00","author":{"@id":"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/4021f481cfccb939861999010538024c"},"breadcrumb":{"@id":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.besteyehospitals.com\/blog\/shaffer-grading-definition-uses-and-clinical-overview\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.besteyehospitals.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Shaffer grading: Definition, Uses, and Clinical Overview"}]},{"@type":"WebSite","@id":"https:\/\/www.besteyehospitals.com\/blog\/#website","url":"https:\/\/www.besteyehospitals.com\/blog\/","name":"My blog","description":"Connecting You to the World\u2019s Best Eye Hospitals","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.besteyehospitals.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/4021f481cfccb939861999010538024c","name":"dreye","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.besteyehospitals.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/69eb63e7f3249514583055a53b7943b46015043634892a817520c7b299ddf648?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/69eb63e7f3249514583055a53b7943b46015043634892a817520c7b299ddf648?s=96&d=mm&r=g","caption":"dreye"},"url":"https:\/\/www.besteyehospitals.com\/blog\/author\/dreye\/"}]}},"_links":{"self":[{"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/posts\/2879","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/comments?post=2879"}],"version-history":[{"count":0,"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/posts\/2879\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/media?parent=2879"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/categories?post=2879"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.besteyehospitals.com\/blog\/wp-json\/wp\/v2\/tags?post=2879"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}